CL5/CL3/CL1Firmware Update Guide 1
CL5/CL3/CL1 Firmware Update Guide
Thank you for choosing a Yamaha product.
This guide explains how to update the CL series (CL5, CL3, and CL1) firmware and its built-in Dante
module firmware.
Important Notice
From V3.10, it was made possible to use a USB memory to also update the Dante module
firmware.
Although the CL series firmware (main/sub) can be updated together at the same time by using
the USB memory to update the Dante module firmware, updating the Dante firmware will take
approximately 30 minutes.
Although using a computer (Dante Firmware Update Manager) to update the Dante firmware in
the conventional manner reduces the amount of time required for the Dante firmware update, it
is necessary to update the CL series firmware by using a USB memory separately.
Precautions (Please be sure to read this section first!)
The user assumes full responsibility for the update.
Update the firmware components one unit at a time.
Please note that the device may be damaged if you fail to follow these instructions properly, or
turn off the device or disconnect the cable while the update is in progress.
If the update fails, and the device still does not operate correctly even after you execute the update
once again, please contact your Yamaha dealer.
Yamaha Corporation owns exclusive copyrights for the CL series firmware, its update program,
and the update guide.
Audinate owns exclusive copyrights for the Dante firmware and its update program.
It is prohibited to duplicate or modify the firmware, software or guides, in part or in their entirety,
without permission from the copyright owner.
The screen shots in this guide are for use with this update procedure only and may be different
from the actual screen shots.
Dante is a registered trademark of Audinate.
Windows is a registered trademark of Microsoft ® Corporation in the United States and other
countries.
The company names and product names in this document are the trademarks or registered
trademarks of their respective companies.
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1 - ■ Important Notice

CL5/CL3/CL1Firmware Update Guide 1 CL5/CL3/CL1 Firmware Update Guide Thank you for choosing a Yamaha product. This guide explains how to update

Pagina 2 - Preparing for the update

CL5/CL3/CL1Firmware Update Guide 10 ・ The “Windows Security” dialog box may appear. In such case, click [Install this driver software anyway].

Pagina 3 - Update procedure sequence

CL5/CL3/CL1Firmware Update Guide 11 6. Click [OK]. Updating the Dante firmware Described below are the procedures to update the Dante modul

Pagina 4

CL5/CL3/CL1Firmware Update Guide 12 3. If you see the interface selection screen, select the interface card to connect the Dante device. 4. Cli

Pagina 5

CL5/CL3/CL1Firmware Update Guide 13 cable might be disconnected or broken, whether the TCP/IP settings are correct, and whether the CL is running

Pagina 6

CL5/CL3/CL1Firmware Update Guide 14 About Failsafe Mode The Dante module integrated in the CL may become unusable due to data corruption if th

Pagina 7

CL5/CL3/CL1Firmware Update Guide 15 Recovery procedure sequence Recover in the following sequence. Preparing for recovery Install the Dante Fi

Pagina 8

CL5/CL3/CL1Firmware Update Guide 16 5. Disable all but one of the network interfaces on your computer. You should also disable the wireless LAN.

Pagina 9

CL5/CL3/CL1Firmware Update Guide 17 13. Exit the Dante Firmware Update Manager, and wait for two minutes before turning off the power to the CL

Pagina 10

CL5/CL3/CL1Firmware Update Guide 2 Checking the version number You may check the CL main firmware version number and the Dante firmware versio

Pagina 11

CL5/CL3/CL1Firmware Update Guide 3 Update procedure sequence Update each firmware component in the following sequence. If you plan to update m

Pagina 12

CL5/CL3/CL1Firmware Update Guide 4 Updating the CL series firmware Described below are the procedures to update the CL series unit firmware. U

Pagina 13 - Restart the CL series

CL5/CL3/CL1Firmware Update Guide 5 power again to resume the initialization. ・ If CL-MD***.BIN (*** indicates the version number) has already

Pagina 14 - Preparing for recovery

CL5/CL3/CL1Firmware Update Guide 6 Updating the CL NAME SUB CPU Firmware Described below are the procedures to update the NAME SUB CPU of the

Pagina 15

CL5/CL3/CL1Firmware Update Guide 7 Service" is displayed. Please contact your Yamaha dealer. Updating the Dante Firmware Described below

Pagina 16

CL5/CL3/CL1Firmware Update Guide 8 3. When firmware loading is completed, the message "Dante Update Successful" is displayed. Click the

Pagina 17

CL5/CL3/CL1Firmware Update Guide 9 Updating the Dante firmware by using PC application. Described below are the procedures to update the Dante

Comentarios a estos manuales

Sin comentarios