CHAPTER2 CC-Link Unit
(27) Counter variable D definition ............................................... Code 011B
The counter variable D is set.
Command option
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
Counter value
Command response
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
(Details)
Counter value:
A value of 0 to 65535 can be specified.
(Example)
Transmission example 1:
200 is set to the counter variable D.
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
RWwn+1
RWwn
0000
0000 0000
0000
0000 00C8
0000 011B
Response example 1:
It is normally ended.
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
RWrn+1
RWrn
0000
0000 0000
0000
0000 0000
0000 0200
MEMO
MEMO
The counter variable D is a variable which can be set as desired by the user, and a
desired value of 0 to 65535 can be set.