15
CHAPTER2 CC-Link Unit
2-5-3 Setting the communication speed
Communication speed can be set to 10M, 5M, 2.5M, 625K, 156K in bps. The communi-
cation speed must match the master station speed.
1) Press
F3
(SYS) on the initial screen.
2) Press
F4
(next) to switch to the func-
tion display and then press
F2
(OPT).
3) Press
F3
(SPD).
4) The currently set communication speed
is displayed. To change the speed, press
the function key matching the new com-
munication speed you want to set. If the
new communication speed does not ap-
pear, press
F4
(next) and the remaining
available communication speeds will ap-
pear.
5) When entry is finished, the screen returns
to 4).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE
2OPT 3UTL 4next
[SYS-OPT]
select menu
1DEV 2NODE3SPD 4next
[SYS-OPT-SPD]
speed = 5M [bps]
110M 25M 32.5M4next
[SYS-OPT-SPD]
speed = 10M [bps]
110M 25M 32.5M4next