Yamaha SRCD Manual de usuario Pagina 118

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 117
112
CHAPTER2 CC-Link Unit
(10) Return-to-origin status check .............................................. Code 020A
It reads that the return-to-origin is completed in all axes or specified axes.
In thee all-axis specification mode, the result becomes 1 only when all axes are
completely returned to the origin.
Command option
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
Axis
Command response
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
Origin status
(Details)
Axis: 0 means all axes, 1 means X axis and 2 means Y axis. On dual-axis
controllers, all axes are also specified when 3 is set.
On single-axis controllers, 0 or 1 alone can be specified.
Origin status: 0 means that the origin is incomplete, and 1 means that the return-
to-origin is completed.
(Example)
Transmission example 1:
It reads that the return-to-origin is completed in all axes.
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
RWwn+1
RWwn
0000
0000 0000
0000
0000 0000
0000 020A
Response example 1:
The return-to-origin is completed in all axes.
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
RWrn+1
RWrn
0000
0000 0000
0000
0000 0001
0000 0200