84
CHAPTER2 CC-Link Unit
(15) General-purpose output or
memory output status change .............................................. Code 010F
ON/OFF control of the general-purpose output or memory output is performed.
Command option
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
Output status
DO/MO/SO
number
Command response
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
(Details)
DO/MO/SOnumber:
One is specified among the general-purpose output 0 to 12 (13
points)*, serial general-purpose output 200 to 231 (32 points) or
memory output 100 to 131 (32 points).
Output status: 1 means ON, and 0 means OFF.
(Example)
Transmission example 1:
The serial general-purpose output 203 is turned ON.
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
RWwn+1
RWwn
0000
0000 0000
0000
0001 00CB
0000 010F
Response example 1:
It is normally ended.
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
RWrn+1
RWrn
0000
0000 0000
0000
0000 0000
0000 0200
* 0 to 4 (5 points) for the SRCP/SRCD series controllers