CHAPTER2 CC-Link Unit
(16) General-purpose input or memory input wait ..................... Code 0110
It waits until the specified general-purpose input or memory input comes into the
specified state.
Command option
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
Input status
DI/MI/SI number
Command response
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
(Details)
DI/MI/SI number:
One is specified among the general-purpose input 0 to 15 (16
points)*, serial general-purpose input 200 to 231 (32 points) or
memory input 100 to 147 (48 points).
Input status: 1 means ON, and 0 means OFF.
(Example)
Transmission example 1:
It waits until SI201=1.
RWwn+7
RWwn+6 RWwn+5 RWwn+4
RWwn+3 RWwn+2
RWwn+1
RWwn
0000
0000 0000
0000
0001 00C9
0000 0110
Response example 1:
It is normally ended.
RWrn+7
RWrn+6 RWrn+5 RWrn+4
RWrn+3 RWrn+2
RWrn+1
RWrn
0000
0000 0000
0000
0000 0000
0000 0200