CHAPTER2 CC-Link Unit
2-16 Specifications
CC-Link Unit
CC-Link version
CC-Link I/O points
*
1
Controller models
Remote station type
Stations used
Station No. setting
Communication speed setting
Minimum length between stations
*
2
Parallel external I/O
Overall length
*
2
Spec. Item
Model
Monitor LED
*
3
Ver. 1.10
SRCP/SRCD/ERCX/SRCX/DRCX series controllers
Remote device station
2 fixed stations
1 to 63 (set from HPB)
10M/5M/2.5/625K/156Kbps (set from HPB)
General-purpose outputs 32 points
General-purpose inputs 32 points
Custom inputs 16 points
Custom outputs 16 points
Input register 8 words (not currently used)
100m (10Mbps)
0.2m or more
160m (5Mbps)
400m (2.5Mbps)
900m (625Kbps)
Output register 8 words (not currently used)
All points usable as parallel external I/O for controller
Each point controllable from master station sequencer (PLC)
by emulated serialization, regardless of robot program.
1200m (156Kbps)
RUN, ERR, SD, RD
*1. Controller I/O rewrite period is every 10ms.
*2. When using cable for CC-Link Ver. 1.10
*3. The upper lid of the controller must be removed in order to monitor the LED.
NOTE: The product external appearance and specifications are subject to change